Not every cable can be buried in duct. Across substations, rail lineside, solar farms, battery storage sites, bridges and industrial plants, cables often run at or near ground level, where they need a protected, accessible route that can be opened for inspection and new circuits. That is the job of cable troughing, and glass reinforced plastic, or GRP, has become one of the most common materials for it.
GRP cable troughing is light, strong, non-conductive and does not rust, but like any route product it has to be specified for the site: the load it will carry, the cables it must hold, the environment it sits in and the security it needs. This guide is written for the people specifying and buying cable troughing. It covers what GRP troughing is, why it is chosen over concrete and steel, the specifications that matter, and a checklist for getting it right.
What GRP cable troughing is
GRP cable troughing is a channel, usually U-shaped, made from polyester or similar resin reinforced with glass fibres, and closed with a removable lid. Cables are laid into the trough rather than pulled through it, and the lid is fitted over them to protect the route. Lengths are joined end to end, with bends, tees and other fittings to follow the route and branch off where circuits split.
It is used wherever cables need protection along a surface or shallow route but also need to stay accessible: across substation compounds, along rail lineside, between rows of panels on solar farms, through battery energy storage sites, along bridges and in tunnels, and around industrial sites. Mountrel’s GRP Cable Trough provides a durable, non-corroding channel for routing and protecting cables in exposed or buried infrastructure, keeping services organised and accessible along the route.
Why GRP instead of concrete or steel
Cable troughing has traditionally been made of concrete or steel, and GRP was developed to solve the problems both bring.
Compared with concrete, GRP is much lighter, so lengths can usually be carried and placed by hand without lifting equipment, which speeds up installation and reduces manual handling risk. It does not crack, chip or spall in frost, and lids are far easier to lift for inspection. Compared with steel, GRP does not corrode, needs no painting or galvanising, and, because it is non-conductive, it does not need bonding or earthing. It also has little or no scrap value, which makes it far less attractive to metal thieves than steel troughing, a real consideration on remote and unattended sites.
The trough is not the asset, the cables inside it are. A route that is easy to open for the team and hard to open for anyone else protects both.
The specifications that matter
When comparing GRP cable troughing, five specifications decide whether it suits the job.
The first is size. The internal width and depth must hold the cables planned for the route, with spare capacity for future circuits, because adding a second trough later costs far more than sizing up now. The second is load rating. Troughing that people will walk on, or that light vehicles might cross, needs a lid and body rated for that load; where heavier vehicle crossings are needed, the route usually changes to buried duct or a rated crossing. The third is lid security. On public-facing or remote sites, lockable or tamper-resistant lid fixings deter cable theft and unauthorised access. The fourth is environment. GRP for outdoor use should be UV stabilised so it does not degrade in sunlight, and fire performance should be checked where the route runs through tunnels, buildings or other enclosed spaces. The fifth is fittings and drainage: bends, tees, end caps and joint arrangements to follow the route, and drainage to stop water collecting in the trough.
Some sectors add their own approvals. On rail, troughing on or near the running line will normally need product acceptance from the infrastructure owner, and utility clients often specify sizes and colours. Confirm these requirements before ordering.
Surface and buried installation
GRP troughing can be installed at ground level, partly sunk, or fully buried, and each approach suits different sites.
Surface troughing sits on a prepared, level base along the route, which is quick to install and easy to inspect, and suits substations, rail lineside and temporary or relocatable routes. Partly sunk troughing, with the lid at or near ground level, reduces trip hazards and keeps the route tidy in areas with foot traffic. Fully buried troughing gives the most protection while still allowing the lid to be exposed for access. In every case, the base needs to be firm, level and well drained, so the trough does not twist, the lids sit flat, and joints stay aligned.
Common failures, and how to avoid them
Most cable troughing problems come down to four failure modes. The first is an undersized trough, full on day one, which forces a second route the first time the site expands. The second is lids that move or go missing, from poor fixing or no security on a remote site, which exposes cables to damage and theft. The third is water collecting in the trough, from no drainage or a poor base. The fourth is a trough not rated for the loads it actually sees, such as foot traffic and site vehicles. Sizing for growth, specifying secure lids, preparing a drained base, and matching the load rating to the site avoids all four.
A specification checklist for GRP cable troughing
Size the internal width and depth for the planned cables plus spare capacity.
Match the lid and body load rating to foot traffic and any vehicle crossings.
Specify lockable or tamper-resistant lid fixings on remote or public-facing sites.
Choose UV-stabilised GRP for outdoor routes, and check fire performance for enclosed spaces.
Plan bends, tees, end caps and drainage along the full route.
Prepare a firm, level, drained base for surface, sunk or buried installation.
Confirm any sector approvals, such as rail product acceptance or utility client specifications.
Frequently asked questions
What is GRP cable troughing?
GRP cable troughing is a channel made from glass reinforced plastic, with a removable lid, used to route and protect cables at or near ground level. Cables are laid into it, and the lid can be lifted for inspection and new circuits.
Why use GRP cable trough instead of concrete?
GRP is much lighter than concrete, so it is quicker and safer to install, and it does not crack or spall. Lids are easier to lift for inspection, and the trough needs little maintenance over its life.
Does GRP cable troughing need earthing?
No. GRP is non-conductive, so unlike steel troughing it does not need bonding or earthing. It also does not corrode.
Where is GRP cable troughing used?
It is used in substations, along rail lineside, on solar farms and battery storage sites, on bridges and in tunnels, and across industrial sites, wherever cables need a protected but accessible route.
Is GRP troughing the same as GRP trunking?
The terms are often used interchangeably. Troughing usually means an open channel with a lid laid at or near ground level, while trunking is more often used for enclosed cable routes fixed to walls or structures.
Related Mountrel products
GRP Cable Trough, a durable, non-corroding cable channel
GRP enclosures and kiosks, for housing network equipment alongside the route
Danger of Death LV signage, for substations and cable routes
Hardened steel padlocks, for securing enclosures and kiosks
See the full GRP range, including troughs, enclosures and kiosks, and read our related piece on IDNO locks and labels.
Talk to Mountrel about GRP cable troughing
Mountrel Electric supplies GRP cable troughing, enclosures and kiosks for UK power, rail, renewables and industrial projects, alongside the signage and security that complete a site, delivered nationwide. If you are specifying troughing for a site, email the team at sales@mountrel.com and we will help you match the size, load rating and fittings to your route.
Get the latest articles and insights delivered straight to your inbox. Sign up today to stay informed and ahead of the competition.