Every new home, shop and small business on a UK electricity network is connected through a short length of cable that most people never see: the service cable that runs from the mains in the street to the cut-out at the property. In the UK that cable is almost always a concentric service cable, and choosing between its two main types, CNE and split concentric SNE, decides how the property is earthed for the life of the connection.
Get the choice wrong and the connection may not meet the network operator’s requirements, or the earthing arrangement may not suit what the customer is installing. This guide is written for the people specifying and buying service cable for new connections. It covers what concentric service cable is, the difference between CNE and SNE, the BS 7870 standards behind them, and how to choose the right cable, size and sheath for the job.
What concentric service cable is
A concentric service cable has an insulated phase conductor, or conductors for a three-phase supply, at its centre, surrounded by a layer of copper wires laid concentrically around it, with an outer sheath over the top. The concentric layer is the return path and the earth path for the supply.
That construction is a safety feature as well as an electrical one. Because the concentric wires completely surround the live conductor, anything that cuts into the cable, such as a spade, a drill or a digger bucket, has to pass through the concentric layer before it can reach the phase. That gives a path to earth and makes a strike far more likely to operate protection than to energise the tool. It is one of the main reasons concentric cable is the standard choice for UK service connections.
The concentric layer wraps the live conductor in its own return and earth path. Anything that cuts in has to get through it first.
CNE and SNE: the difference that matters
The two main types of concentric service cable differ in what the concentric layer does, and that sets the earthing system at the property.
In a CNE cable, short for combined neutral and earth, the concentric copper layer acts as both the neutral and the earth. This is the cable used for TN-C-S supplies, often called PME, where the network operator provides an earth terminal at the cut-out that is connected to the combined neutral. Mountrel’s Concentric CNE Service cable is built for exactly this: a combined neutral and earth copper concentric conductor for TN-C-S supplies, made to BS 7870-3.11.
In a split concentric cable, also called SNE for separate neutral and earth, the concentric layer is divided into two separate sets of wires: one carries the neutral and the other provides a separate protective earth. This is the cable for TN-S supplies, where neutral and earth stay separate all the way back to the network. Mountrel’s Split Concentric SNE Service cable is made to BS 7870-3.21 for TN-S connections and for sites that need separate neutral and earth paths.
Which supply type do you need?
For most new domestic and small commercial connections, UK network operators provide a TN-C-S (PME) supply, and CNE concentric is the standard service cable. It is simpler, widely stocked and what most connection designs specify.
Split concentric SNE is used where a TN-S supply is wanted or required: where the network operator specifies it, where the existing network in the area is TN-S, or where the customer’s installation calls for a separate earth. Some installations have restrictions or extra requirements on using a PME earth, for example petrol filling stations, and some supplies to EV charge points, marinas, caravan parks and construction sites, so the earthing arrangement should be confirmed with the network operator and the installation designer before the service cable is ordered.
BS 7870: the standards behind service cable
Low-voltage distribution and service cables for UK networks are specified to BS 7870. Within it, BS 7870-3.11 covers CNE concentric service cable and BS 7870-3.21 covers split concentric service cable. Specifying cable to the correct part of the standard is the simplest way to make sure it will be accepted by the DNO or IDNO adopting the connection.
Network operators then set their own requirements on top, including conductor size and material, sheath type and how the cable is terminated at the cut-out and jointed to the main. Our CNE and SNE service cables are supplied for use across UKPN, NGED, SSE, SPEN, ENWL, NPg and IDNO networks.
Choosing size, conductor and sheath
Once the cable type is set, three choices finish the specification.
The first is size. As a common working pattern, 25mm² concentric is used for single-phase services and 35mm² for three-phase services, with larger sizes available for bigger loads or longer runs. The second is conductor material: service cable is available with copper or aluminium conductors, and the network operator’s specification usually decides which. The third is sheath. CNE service cable is available with a PVC or MDPE sheath, while split concentric SNE is available in black PVC or in orange LSOH, low smoke zero halogen, for installations in sensitive environments where smoke and fumes in a fire are a concern.
Ordering cut to length, rather than in standard drum lengths only, keeps waste down on connection programmes where every service run is a different length.
Completing the connection
The service cable is one part of a connection that runs from the main in the street to the meter. At the network end, it is jointed onto the LV main, often a waveform CNE mains cable, using an LV branch joint. At the property end, it terminates in the cut-out, which houses the service fuse and provides the network earth terminal on a PME supply. Specifying the cable, joint and cut-out together, all suited to the same network operator’s requirements, avoids mismatched parts at energisation.
A specification checklist for concentric service cable
Confirm the earthing system with the network operator: TN-C-S (PME) or TN-S.
Specify CNE to BS 7870-3.11 for TN-C-S, or split concentric SNE to BS 7870-3.21 for TN-S.
Check for installations with PME restrictions, such as petrol filling stations, EV charging, marinas and construction sites.
Choose the size for the load: commonly 25mm² single phase and 35mm² three phase, larger on request.
Follow the network operator’s specification for copper or aluminium conductors.
Choose the sheath: PVC or MDPE for CNE, black PVC or orange LSOH for SNE.
Specify the branch joint and cut-out alongside the cable, all to the same network’s requirements.
Frequently asked questions
What is a concentric service cable?
A concentric service cable has an insulated phase conductor at its centre surrounded by a concentric layer of copper wires, which provides the neutral and earth path. It is the standard cable for connecting UK properties from the street main to the cut-out.
What is the difference between CNE and SNE cable?
In CNE cable the concentric layer is a combined neutral and earth, used for TN-C-S (PME) supplies. In split concentric SNE cable the concentric layer is split into separate neutral and earth conductors, used for TN-S supplies.
Which BS 7870 part covers concentric service cable?
BS 7870-3.11 covers CNE concentric service cable, and BS 7870-3.21 covers split concentric service cable.
What size service cable is used for a house?
A common pattern is 25mm² concentric for a single-phase service and 35mm² for a three-phase service, with larger sizes for bigger loads. The network operator’s design sets the final size.
When is LSOH service cable used?
Orange LSOH split concentric cable is used where low smoke and zero halogen performance is needed in a fire, such as inside buildings with escape routes or other sensitive environments.
Related Mountrel products
Concentric CNE Service, to BS 7870-3.11 for TN-C-S supplies
Split Concentric SNE Service, to BS 7870-3.21 for TN-S supplies
Waveform LV Mains, the LV main the service is jointed to
LV Branch Joint, for jointing the service onto the main
200A Heavy Duty Cut-Out, for terminating the service at the property
See the full cables range and cut-outs, heads and metering range, and our related guide on specifying GRP cable troughing.
Talk to Mountrel about concentric service cable
Mountrel Electric supplies concentric service cable for UK connections: CNE to BS 7870-3.11 and split concentric SNE to BS 7870-3.21, in copper or aluminium, with PVC, MDPE or LSOH sheaths, cut to length and supplied on drum for every major DNO and IDNO network. If you are specifying service cable for a connections programme, email the team at sales@mountrel.com and we will help you match the cable, joints and cut-outs to your network’s requirements.